How to Configure VLAN, STP, DTP
In this tutorial I will demonstrate that how can you- Configure Access or Trunk links
- Create VLAN
- Assign VLAN membership
- Configure Intra VLAN routing
- Configure VTP Server
- Make VTP Clients
- Show STP Static
- Configure DTP port
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Task
You are the administrator at ComputerNetworkingNotes.com. company have two department sales and management. You have given three pc for sales and three pc in management. You created two VLAN. VLAN 10 for sales and VLAN20 for management. For backup purpose you have interconnected switch with one extra connection. You have one router for intera VLAN communications.Let's start configuration first assign IP address to all pc's
To assign IP address double click on pc and select ip configurations from desktop tab and give ip address as shown in table given above
VLAN Trunking Protocol
Configure VTP Server
We will first create a VTP Server so it can automatically propagate VLAN information to other switch. Double click on Switch1 and select CLI. Set hostname to S1 and create VTP domain name example and set password to vinita ( Remember password is case sensitive ).Switch 1
Switch>enable Switch#configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch(config)#hostname S1 S1(config)#vtp mode server Device mode already VTP SERVER. S1(config)#vtp domain example Changing VTP domain name from NULL to example S1(config)#vtp password vinita Setting device VLAN database password to vinita
Configure VTP clients
Once you have created a VTP domain. Configure remaining Switch to Client mode.Switch 2
Switch>enable Switch#configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch(config)#hostname S2 S2(config)#vtp mode client Setting device to VTP CLIENT mode. S2(config)#vtp domain example Changing VTP domain name from NULL to example S2(config)#vtp password vinita Setting device VLAN database password to vinita S2(config)#
Switch>enable Switch#configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch(config)#hostname S3 S3(config)#vtp mode client Setting device to VTP CLIENT mode. S3(config)#vtp domain example Changing VTP domain name from NULL to example S3(config)#vtp password vinita Setting device VLAN database password to vinita S3(config)#
Dynamic Trunking Protocol
Configure DTP port
All Switch ports remain by default in access mode. Access port can not transfer the trunk frame. Change mode to trunk on all the port those are used to interconnect the switchesSwitch 1
S1(config)#interface fastEthernet 0/24 S1(config-if)#switchport mode trunk %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/24, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/24, changed state to up S1(config-if)#exit S1(config)#interface gigabitEthernet 1/1 S1(config-if)#switchport mode trunk S1(config-if)#exit S1(config)#interface gigabitEthernet 1/2 S1(config-if)#switchport mode trunk %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/2, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/2, changed state to up S1(config-if)#exit S1(config)#
S2(config)#interface gigabitEthernet 1/1 S2(config-if)#switchport mode trunk %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/1, changed state to up S2(config-if)#exit S2(config)#interface gigabitEthernet 1/2 S2(config-if)#switchport mode trunk S2(config-if)#exit S2(config)#interface fastEthernet 0/23 S2(config-if)#switchport mode trunk %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/23, changed state to down %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/23, changed state to up S2(config-if)#exit S2(config)#interface fastEthernet 0/24 S2(config-if)#switchport mode trunk S2(config-if)#exit
S3(config)#interface fastEthernet 0/24 S3(config-if)#switchport mode trunk S3(config-if)#exit S3(config)#interface gigabitEthernet 1/1 S3(config-if)#switchport mode trunk S3(config-if)#exit
Virtual LAN (VLAN)
Create VLAN
After VTP server configuration its time to organize VLAN. We need only to create VLAN on VTP server and reset will be done by VTP Server automatically.Switch 1
S1(config)#vlan 10 S1(config-vlan)#exit S1(config)#vlan 20 S1(config-vlan)#exit S1(config)#
Assign VLAN membership
Switch 1S1(config)#interface fastEthernet 0/1 S1(config-if)#switchport access vlan 10 S1(config-if)#interface fastEthernet 0/2 S1(config-if)#switchport access vlan 20
S2(config)#interface fastEthernet 0/1 S2(config-if)#switchport access vlan 10 S2(config-if)#interface fastEthernet 0/2 S2(config-if)#switchport access vlan 20
S3(config)#interface fastEthernet 0/1 S3(config-if)#switchport access vlan 10 S3(config-if)#interface fastEthernet 0/2 S3(config-if)#switchport access vlan 20
Spanning-Tree Protocol
In this configuration STP will block these ports F0/24 of S1 , F0/23 and F0/24 of S2 and F0/24 of S3 to avoid loop at layer to two. Verify those ports blocked due to STP functionsVerify STP ports
Switch 2S2#show spanning-tree active VLAN0001 Spanning tree enabled protocol ieee Root ID Priority 32769 Address 0002.174D.7794 Cost 4 Port 26(GigabitEthernet1/2) Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 32769 (priority 32768 sys-id-ext 1) Address 00D0.FF08.82E1 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Aging Time 20 Interface Role Sts Cost Prio.Nbr Type ---------------- ---- --- --------- -------- --------------------------- Fa0/1 Desg FWD 19 128.1 P2p Fa0/2 Desg FWD 19 128.2 P2p Fa0/23 Desg FWD 19 128.23 P2p Fa0/24 Altn BLK 19 128.24 P2p Gi1/1 Desg FWD 4 128.25 P2p Gi1/2 Root FWD 4 128.26 P2p [Output is omitted] S2#
show spanning-tree active command
Router on Stick
Switch#show interfaces vlan x | Displays interface characteristics for the specified VLAN |
Switch#delete flash:vlan.dat Delete filename [vlan.dat]? Delete flash:vlan.dat? [confirm] Switch# | Removes the entire VLAN database from flash. Make sure there is no space between the colon (:) and the characters vlan.dat. You can potentially erase the entire contents of the flash with this command if the syntax is not correct. Make sure you read the output from the switch. If you need to cancel, press ctrl+c to escape back to privileged mode: |
Switch(config)#interface fastethernet 0/5 | Moves to interface configuration mode. |
Switch(config-if)#no switchport access vlan 5 | Removes port from VLAN 5 and reassigns it to VLAN 1—the default VLAN. |
Switch(config-if)#exit | Moves to global configuration mode. |
Switch(config)#no vlan 5 | Removes VLAN 5 from the VLAN database. |
Switch#copy running-config startupconfig | Saves the configuration in NVRAM |
Switch(config-if) #switchport mode trunk | Puts the interface into permanent trunking mode and negotiates to convert the link into a trunk link. |
Switch(config)#vtp mode server | Changes the switch to VTP server mode. |
Switch(config)#vtp mode client | Changes the switch to VTP client mode. |
Switch(config)#vtp mode transparent | Changes the switch to VTP transparent mode. |
Switch(config)#no vtp mode | Returns the switch to the default VTP server mode. |
Switch(config)#vtp domain domain-name | Configures the VTP domain name. The name can be from 1 to 32 characters long. |
Switch(config)#vtp password password | Configures a VTP password . |
Switch(config)#vtp pruning | Enables VTP pruning |
Switch#show vtp status | Displays general information about VTP configuration |
Switch#show vtp counters | Displays the VTP counters for the switch |
No comments: